Heat Press Temperature Conversion Chart printable table preview
Printable image of the sourced heat press temperature conversion chart.

Heat Press Temperature Conversion Chart

Use this quick chart when a manufacturer gives one unit; enter the converted value only after confirming the original instruction.

FahrenheitCelsiusCommon referenceConversionSource
250°F121.1°CLow-temperature film(250−32)×5/9[S1][S2]
265°F129.4°CLow-temperature film(265−32)×5/9[S1][S2]
275°F135.0°CLow-temperature film(275−32)×5/9[S1][S2]
280°F137.8°CPuff / performance range(280−32)×5/9[S1][S2]
285°F140.6°CMetallic range(285−32)×5/9[S1][S2]
290°F143.3°CDTF / glitter range(290−32)×5/9[S1][S2]
300°F148.9°CCommon HTV range(300−32)×5/9[S1][S2]
305°F151.7°CCommon HTV range(305−32)×5/9[S1][S2]
320°F160.0°CSpecialty HTV range(320−32)×5/9[S1][S2]
400°F204.4°CSublimation range(400−32)×5/9[S1]

How to use the Heat Press Temperature Conversion Chart

  1. Identify the exact material or garment.
  2. Read the complete row and its bracketed source key.
  3. Open the source and confirm the current manufacturer instruction.
  4. Run and record one test before repeating the setup.

Real-world examples

First sample

Inputs

  • Exact product
  • One sourced row

Result

A single test setup

Production check

Do not generalize the row to an unnamed substitute.

Units and parameters

Keep units consistent from design setup through pressing notes. When the tool provides a preset, use it as a planning value and replace it with the actual garment or blank measurement when possible.

Input or ruleWhat it changes
FahrenheitRead the fahrenheit value in the same row; do not mix columns from different products.
CelsiusRead the celsius value in the same row; do not mix columns from different products.
Common referenceRead the common reference value in the same row; do not mix columns from different products.
ConversionRead the conversion value in the same row; do not mix columns from different products.
SourceRead the source value in the same row; do not mix columns from different products.

Rule and assumptions

Use the row for the exact named material or garment. Bracketed source keys identify the manufacturer or supplier table behind that row.

  • Values apply to the named product or blank, not every material in the same category.
  • Measure the actual garment or blank and test one item before a production batch.
  • Press calibration, platen contact, seams, moisture, and finish can change a result.

Use this tool for

  • Preparing a repeatable bench reference
  • Comparing product-specific values before a test
  • Recording the source used for an order

Worked example

Inputs

  • One exact table row
  • The linked source revision
  • The actual blank or garment

Result

A sourced starting value and a written test note

When to use this

Before cutting or pressing a new product combination.

What to check before pressing

Confirm product name, substrate, source revision, press calibration, and platen contact.

Quick reference chart

Use caseStarting pointCheck before pressing
250°F121.1°C · Low-temperature film · (250−32)×5/9[S1][S2]
265°F129.4°C · Low-temperature film · (265−32)×5/9[S1][S2]
275°F135.0°C · Low-temperature film · (275−32)×5/9[S1][S2]
280°F137.8°C · Puff / performance range · (280−32)×5/9[S1][S2]
285°F140.6°C · Metallic range · (285−32)×5/9[S1][S2]
290°F143.3°C · DTF / glitter range · (290−32)×5/9[S1][S2]
300°F148.9°C · Common HTV range · (300−32)×5/9[S1][S2]
305°F151.7°C · Common HTV range · (305−32)×5/9[S1][S2]
320°F160.0°C · Specialty HTV range · (320−32)×5/9[S1][S2]
400°F204.4°C · Sublimation range · (400−32)×5/9[S1]

Common mistakes

  • Using a similarly named product instead of the exact row.
  • Skipping the linked source when a manufacturer revises instructions.
  • Repeating a batch before checking one sample and platen contact.

Sources

Table rows use the source keys shown in brackets. Recheck the linked manufacturer instructions for the exact material, blank, and press before production.

  1. [S1] NIST Guide for the Use of the International System of Units — SI conversion guidance; °C = (°F − 32) × 5/9.
  2. [S2] STAHLS Application Instructions — Manufacturer examples of common heat-press Fahrenheit settings.

FAQ

Are the numbers in this heat press temperature conversion chart universal?

No. Each row is tied to the named material or garment and its bracketed source. Recheck the source and test the actual item.

Why do I need a test when the row has a source?

A source establishes the intended starting value. Press calibration, substrate variation, seams, moisture, and finish still affect the physical result.

How should I record a changed setting?

Keep the source value and the successful test value together with the product name, date, press, pressure method, and blank lot.